Home Frequently
Asked Questions Contact
Us Site
Map |
|
|
|
|
Ground Support Equipment (GSE) and Tractors DC Motor
Controls
Navitas Technologies
has promoted products to the GSE market for over 15 years. With reliable
control and full programmability, Navitas DC motor controllers offer
higher efficiency and packaging density than previously possible. We
work with OEMs to customize controllers to meet specific requirements.
| Controller with Vehicle
Logic (Fully Programmable) |
| Voltage |
Peak Current |
Part Number |
Throttle Type(s) |
HPD |
Plug |
Contactorless Motor Reversing |
Regen |
Datasheet |
Manual |
| 24-48 |
400 |
TPM400-48 |
0-5k, 5-0k, 0-5v, 5-0v, Bi-directional |
Y |
N |
Y |
Y |
|
|
| *** LOWER CURRENT VERSION COMING SOON!
*** |
|
|
|
|
|
|
|
* TPM controllers require the use of a TPM-Probit-Win
programming package and a Windows based computer for installation and
diagnostics
| Controller with Vehicle
Logic (Fully Programmable) |
| Voltage |
Peak Current |
Part Number |
Throttle Type(s) |
HPD |
Plug |
Contactorless Motor Reversing |
Regen |
Datasheet |
Manual |
| 24-48 |
550 |
TSE550-48 |
0-5k, 5-0k, 0-5v, 5-0v, Bi-directional |
Y |
Y |
N |
N |
|
|
| 24-48 |
1000 |
TSE1000-48 |
0-5k, 5-0k, 0-5v, 5-0v, Bi-directional |
Y |
Y |
N |
N |
|
|
| 96 |
600 |
TSE600-96 |
0-5k, 5-0k, 0-5v, 5-0v, Bi-directional |
Y |
Y |
N |
N |
|
|
** TSE controllers require the use of a PB200-00
hand-held programmer for installation and diagnostics.
*** TSE controllers can also be mounted with 1204/1205 mounting patterns (space permitting).
| Small Vehicle with
Minimal Vehicle Logic (Adjustable, Non-Programmable) |
| Voltage |
Peak Current |
Part Number |
Throttle Type(s) |
HPD |
Plug |
Contactorless Motor Reversing |
Regen |
Datasheet |
Manual |
Style |
| 24-36 |
275 |
CTL-2000 |
0-5k |
Y |
Y |
N |
N |
|
|
1204 |
| 24-36 |
275 |
CTL-2000-05 |
0-5v |
Y |
Y |
N |
N |
|
|
1204 |
| 24-36 |
400 |
CTL-2001 |
0-5k |
Y |
Y |
N |
N |
|
|
1205 |
| 24-36 |
210 |
CTL-2002 |
0-5k |
Y |
Y |
N |
N |
|
|
1204 |
| 24-36 |
275 |
CTL-2003 |
6v-11v |
Y |
Y |
N |
N |
|
|
1204 |
| 24-36 |
400 |
CTL-2004 |
6v-11v |
Y |
Y |
N |
N |
|
|
1205 |
| 24-36 |
400 |
CTL-2010 |
5-0k |
N |
Y |
N |
N |
|
|
1205 |
| 36-48 |
350 |
CTL-2020 |
0-5k |
Y |
Y |
N |
N |
|
|
1205 |
| 36-48 |
450 |
CTL-2021 |
0-5k |
Y |
Y |
N |
N |
|
|
1204 |
| 12 |
400 |
CTL-2022 |
5k-0 |
N |
Y |
N |
N |
|
|
1205 |
| 36-48 |
275 |
CTL-2023 |
0-5k |
Y |
Y |
N |
N |
|
|
1204 |
| 36-48 |
275 |
CTL-2023-HPR |
0-5k |
N |
Y |
N |
N |
|
|
1204 |
| 12 |
275 |
CTL-2025 |
0-5k |
Y |
Y |
N |
N |
|
|
1204 |
| 24-36 |
275 |
CTL-2200 |
0-5k |
Y |
N |
N |
N |
|
|
1204 |
*** We are able to offer various other PMC
replacements. Please contact Navitas with
your requirements.
| Small Vehicle with
Small footprint (Non-Programmable, Non-Adjustable) |
| Voltage |
Peak Current |
Part Number |
Throttle Type(s) |
HPD |
Plug |
Contactorless Motor Reversing |
Regen |
Datasheet |
Manual |
| 12 |
100 |
TSP100-12 |
0-5k, 0-5v |
N |
N |
N |
N |
|
|
| 24-36 |
100 |
TSP100-36 |
0-5k, 0-5v |
N |
N |
N |
N |
|
|
| 36-48 |
200 |
TSP200-48 |
0-5k |
Y |
N |
N |
N |
|
|
| 36-48 |
300 |
TSP300-48 |
0-5k |
Y |
N |
N |
N |
|
|
| 36-48 |
400 |
TSP400-48 |
0-5k |
Y |
N |
N |
N |
|
|
| 36-48 |
200 |
TSP200-48H |
0-5v |
Y |
N |
N |
N |
|
|
| 36-48 |
300 |
TSP300-48H |
0-5v |
Y |
N |
N |
N |
|
|
| 36-48 |
400 |
TSP400-48H |
0-5v |
Y |
N |
N |
N |
|
|
|
|
|
|
|
|
|
| ©2007 Navitas Technologies, Ltd. A member of the Tersus Energy Plc. group of companies. |
|